HardieSmart® Fire-Rated Wall Systems
NCC Compliance Without the Guesswork
The NCC’s fire and acoustic requirements for residential buildings aren’t a checklist you can eyeball your way through. A fire resistance level is a tested, certified property of a complete wall assembly; frame, insulation, lining and fixings are all specified and installed in the configuration that was tested. Get any part of it wrong and the system doesn’t perform as rated, regardless of how close it looks to the tested configuration.
The HardieSmart® System Range
HardieSmart® ZeroLot Wall System
Designed for zero-lot-line construction, where a building is constructed at or very close to the property boundary and the external wall must achieve the required FRL without any setback from the adjacent site.
HardieSmart® Intertenancy Wall System
The system for separating walls between sole-occupancy units in Class 2 buildings, apartments, townhouses and dual-occupancy developments. The intertenancy wall must achieve both a fire resistance level and a sound transmission rating, and HardieSmart® delivers both in a single tested assembly.
HardieSmart® Boundary Wall System
HardieSmart® Blade Wall System
Understanding Fire Resistance Levels
NCC Scenario
Required FRL (typical)
Boundary wall — Class 1
60/60/60 (single storey) · 90/90/90 (two-storey)
Intertenancy wall - Class 2
60/60/60 (apartments), with STC acoustic requirement
ZeroLot wall
60/60/60 to 90/90/90, depending on configuration
Aged care - Class 9
60/60/60 minimum, often higher depending on building classification
Important note
FRL requirements vary by NCC Volume, building class, storey and jurisdiction, always confirm with your certifier before specifying
What Comes With Every HardieSmart® Order
Full technical documentation
Each HardieSmart® system comes with a complete technical package, tested FRL data, an STC acoustic rating, an installation guide and system details. Everything a building certifier needs to assess compliance.
CSIRO-assessed performance
HardieSmart® fire performance data is based on fire resistance testing conducted to Australian Standard AS 1530.4. The boundary wall system has been specifically assessed by the CSIRO Division of Building Construction.
Acoustic ratings supplied
Where acoustic performance is specified (intertenancy and aged care systems), tested STC and IIC data is provided with the system documentation –, not estimated but tested.
Structural bracing data
HardieSmart® systems provide structural bracing capacity for the building frame. Bracing ratings and fixing requirements are documented in the system design guides, typically 4 kN/m for standard configurations.